MPS5000 Series 80GHz FMCW Radar Level Transmitters

MPS5000 Series 80GHz FMCW Radar Level Transmitters

The MPS5000 Series is an 80GHz FMCW radar level measurement system designed for continuous measurement of liquid and solid materials. With different antenna structures and process connection options, the series covers a range of applications, from small liquid containers and compact installations to large solid material silos and demanding process conditions.
Send Inquiry
Description
80GHz

Key Features of MPS5000 Series 80GHz FMCW Radar Level Transmitters

Designed for Flexible Industrial Level Measurement

 

  • 80GHz FMCW Technology:MPS5100 Radar Level Meter Uses W-band frequency-modulated continuous wave radar, with a signal frequency range of 76–81GHz.
  • Narrow Beam Angle:The minimum beam angle can reach 3° with selected antenna configurations.
  • Near-Zero Blind Zone:Almost no blind zone near the instrument, supporting level measurement in small containers.
  • Long Measuring Range:Selected configurations support measuring ranges of up to 120m.
  • Convenient Parameter Setup:Simple display interface, quick setup menu, button operation and local configuration using a HART communicator.

Find the Right Industrial Radar Level Sensor.

Compare MPS 5000 Series FMCW Radar Level Meter for Different Measurement Applications

MPS5100

MPS5100 – Standard Plastic Antenna

MPS5200

MPS5200 – Integrated and Hygienic Antenna

MPS5101

MPS5101 – Compact Plastic Antenna

MPS5300

MPS5300 – PTFE Process-Sealed Antenna

MPS5000 Series Technical Comparison

 

This Industrial Radar Level Meter table helps users compare the four models before reviewing detailed specifications.

Comparison MPS5100 MPS5101 MPS5200 MPS5300
Antenna Design Plastic Rod / Horn Compact Plastic / Horn Integrated / Hygienic / Universal Process-Sealed
Main Application Simple-process liquids and solids Simple-process liquids and solids Mildly corrosive liquids, food and pharmaceutical liquids, solids with specified antenna Strongly corrosive liquids
Antenna Diameter Ø50 / Ø80mm Ø50 / Ø80mm Ø50 / Ø80mm Ø50 / Ø80mm
Maximum Range 30 / 120m 35m
30 / 120m
30/120m
Minimum Beam Angle 7° / 3° 8° / 3° 7° / 3° 7° / 3°
Process Material PTFE / PP + PTFE PP / PP + PTFE 304 + PTFE 304 + PTFE
Process Temperature -40 to 130°C -40 to 80°C -40 to 200°C -40 to 200°C
Process Pressure -1 to 2.5kgf/cm² -1 to 2.5kgf/cm² Depends on antenna type

-1 to 25kgf/cm²

Protection Rating IP66/IP67 IP67 IP66/IP67 IP66/IP67

 

Important Notes:

 

  • The listed maximum range and beam angle depend on the selected antenna configuration.
  • MPS5200 process pressure differs between hygienic, integrated and universal antenna configurations.
  • The ±2mm accuracy is the maximum accuracy under standard laboratory conditions.
  • Actual measuring range and accuracy are affected by antenna size, medium reflectivity, installation position and possible interfering reflections.

 

Not Sure Which Liquid Tank Level Measurement Configuration Fits Your Application?

Tell us your medium, tank dimensions and operating conditions. Our technical team can help you identify a suitable MPS7000 model.

[Request Technical Support]

 

Working Principle -Industrial Tank Level Measurement

How Does an 80GHz Radar Level Transmitter Work?

How-FMCW-Radar-Level-Measurement-Works

01. What Is FMCW Technology?

 

FMCW (Frequency Modulated Continuous Wave) is a radar measurement technology that continuously transmits frequency-modulated microwave signals and measures the frequency difference between transmitted and received signals.

 

 

 

02. How Does It Measure Level?

  • Signal Transmission: The radar antenna transmits frequency-modulated microwave signals toward the material surface.
  • Signal Reflection: The signal is reflected by the material surface and received by the antenna.
  • Signal Processing: The instrument analyzes the frequency difference between the transmitted and received signals to calculate the distance to the material surface.
  • Level Calculation: The measured distance is converted into a level value based on the configured tank dimensions.

 

03. Why Use FMCW Radar Level Transmitter Technology?

 

  1. Narrow Beam Angle: Minimum beam angle of 3°.
  2. High Measurement Accuracy: Maximum accuracy of ±2 mm under standard laboratory conditions.
  3. Long Measuring Range: Up to 120 m, depending on model and antenna configuration.

 

MPS5000 Series 80GHz FMCW Radar Level Transmitters Applications

 

Application

Recommended Model / Configuration Based on the Manual

Liquid Measurement in Small Containers

MPS5100 Ø50mm plastic rod antenna

Simple-Process Liquid Measurement

MPS5100 or MPS5101, according to range and antenna

Lump and Powder Measurement

MPS5100, MPS5101 or MPS5200 with the corresponding antenna

Mildly Corrosive Liquid Measurement

MPS5200 integrated antenna

Food and Pharmaceutical Liquid Measurement

MPS5200 hygienic antenna

Strongly Corrosive Liquid Measurement

MPS5300 process-sealed antenna

Large Solid Silo Measurement

Select the appropriate model and antenna according to range and installation conditions

Mixing Tank and Reactor Measurement

Select according to the process medium and installation conditions

 

Typical Application Scenes

  • Mixing Tanks
  • Small Storage Tanks
  • Reactors
  • Space-Limited Installations
  • Tall Standpipes
  • Large Solid Material Silos
  • Stockpiles

 

 Installation Considerations for 80GHz Radar Level Transmitter 

21

Mixing Tanks

 
22

Solids Bin Installation

 
32

Flat-top Tank 

 
42

Conical-top Tank ;

Dome-roof Tank

 

  • Keep the instrument away from the filling inlet and falling material.
  • Maintain a minimum distance of 200mm from the tank wall.
  • Do not install the instrument at the center of conical or domed tanks.
  • For solid silos, try to point the antenna toward the discharge outlet.
  • For mixing tanks, install the instrument approximately halfway between the outer edge of the agitator blades and the tank wall.
  • Keep obstacles outside the microwave beam angle.
  • Select an accessible position for installation, wiring and future maintenance.

 

 Technical Selection Support

Technical Inquiry & Model Selection

Need Help Selecting the Right MPS5000 Model?

To recommend a suitable model and antenna configuration, please provide the following information:

 

Required Information

Details

Measured Medium

Liquid / Solid

Material Name

Name and relevant characteristics

Measuring Range

Required measuring range

Tank Height

Total tank or silo height

Process Temperature

Minimum / Normal / Maximum

Process Pressure

Operating pressure

Installation Type

Top-mounted / Standpipe / Other

Process Connection

Thread / Flange / Hygienic Clamp

Output Requirement

4–20mA / HART / RS485 Modbus, where available

Special Requirements

Corrosion, hygiene or other process requirements

Radar Level Meter Supplie for you!

2026-11-04112929500-

Send Us Your Application Details

 

 

 

FAQ 

What is the measuring range of the MPS5000 radar level transmitter?

 The MPS5000 Series offers measuring range options of up to 120 meters. The actual range depends on the specific model, antenna configuration and application conditions.

Can the MPS5000 measure both liquids and solids?

Yes. The series includes configurations for liquid and solid level measurement. Different antenna types are available for selected liquids, powders and lump materials.

What is the measurement accuracy of the MPS5000 Series?

The maximum measurement accuracy is ±2 mm under standard laboratory conditions. Actual performance depends on antenna size, medium reflectivity, installation position and possible interference reflections.

Can the MPS5000 measure corrosive liquids?

Yes. The MPS5300 configuration uses a 304 + PTFE process  antenna for selected strongly corrosive liquid applications. The medium compatibility should be confirmed before selection.

How do I choose the right radar antenna?

Antenna selection depends on the measuring medium, required range, tank structure, process conditions and available installation space. Please provide your application details for technical evaluation.

What information should I provide when requesting a quotation?

As Radar Level Meter Manufacturer,Please provide the measuring medium, tank height, required measuring range, process temperature, pressure, connection type and output requirements. A tank drawing or installation photo can also help with model selection.

More Than a Product – Radar Level Transmitter Supplier

Technical Support for Your Application 

 

Application-Based Selection

 

Technical Communication

Order & Delivery Coordination

After-Sales Assistance

Discuss Your Project

 

 

 

 

Hot Tags: mps5000 series 80ghz fmcw radar level transmitters, China mps5000 series 80ghz fmcw radar level transmitters manufacturers, suppliers, factory

Send Inquiry