MPS7000 Series 120 GHz FMCW Radar Level Transmitter

MPS7000 Series 120 GHz FMCW Radar Level Transmitter

MPS7000 Series 120 GHz FMCW Radar Level Transmitter are sensors and gauges used to determine the exact position or volume of liquids, powders, or granular materials inside a container or vessel. These instruments are broadly categorized into point level detection (identifying when a material reaches a specific threshold) and continuous level measurement (tracking the real-time level across an entire range).
Send Inquiry
Description
Level-Measurement-Instruments-2

Key Features of MPS7000 Series 120 GHz FMCW Radar Level Transmitter

  • Highly Focused Beam: Ultra-narrow beam angle, down to 1°.Non Contact Radar Level Meter.
  • Strong Signal: Excellent penetration and extended measuring range.
  • Minimal Blind Zone: Near-zero blind zone for accurate measurement in small vessels.
  • Easy Configuration: Multiple setup options via instrument keys, Bluetooth, PC software, or HART communicator.

MPS7000 Series 120 GHz FMCW Radar Level Transmitter Specification 

Parameter Specification
Beam Angle Min. 1°
Measurement Accuracy

±2 mm

Max. Measuring Range 120 m
Radar Frequency 120GHz
Protection Rating IP66/IP67
Signal Frequency

D-Band (Approx. 120 GHz)

Radar Level Transmitter Detailed Model Selection

1

MPS7100 – Standard FMCW Radar Level Transmitter

Features plastic rod and plastic horn antennas for liquid and solid level measurement under relatively simple process conditions.
 

 

2

MPS7101 – Compact FMCW Radar Level Meter

Features compact plastic and integrated antenna configurations for applications requiring a compact instrument structure.
4

MPS7200 – Integrated & Sanitary FMCW industrial Radar Level Transmitter

Features integrated and hygienic antenna configurations, with optional universal and purge structures.
5

MPS7300 – PTFE Process-Sealed FMCW Radar Level Transmitter

Designed for strongly corrosive liquid measurement under complex process conditions, featuring a PTFE process-sealed antenna.

Not Sure Which Radar Level Transmitter Configuration Fits Your Application?

Tell us your medium, tank dimensions and operating conditions. Our technical team can help you identify a suitable MPS7000 model.

[Request Technical Support]

120 GHz FMCW Radar Measurement Principle

How-FMCW-Radar-Level-Measurement-Works

01. What Is FMCW Technology?

 

FMCW (Frequency Modulated Continuous Wave) is a radar measurement technology that continuously transmits frequency-modulated microwave signals and measures the frequency difference between transmitted and received signals.

 

 

 

02. How Does FMCW Radar Level Meter Measure Level?

  • Signal Transmission: The radar antenna transmits frequency-modulated microwave signals toward the material surface.
  • Signal Reflection: The signal is reflected by the material surface and received by the antenna.
  • Signal Processing: The instrument analyzes the frequency difference between the transmitted and received signals to calculate the distance to the material surface.
  • Level Calculation: The measured distance is converted into a level value based on the configured tank dimensions.

 

03. Why Use 120 GHz FMCW Technology?

Narrow Beam Angle: Minimum beam angle of 1°.

High Measurement Accuracy: Maximum accuracy of ±2 mm under standard laboratory conditions.

Long Measuring Range: Up to 120 m, depending on model and antenna configuration.

 

120GHz Radar Level Meter

Widely Used in Application

1.Liquid Storage Tanks

Continuous level measurement of liquids in storage tanks, including small tanks and industrial storage vessels.

 

2.Mixing Tanks & Reactors

Level monitoring in mixing tanks and reaction vessels, with antenna configurations selected according to internal structures and process conditions.

 

3.Powder & Bulk Material Silos

Continuous level measurement of powder and lump materials in industrial silos and bulk storage vessels.

 

4.Mining & Material Handling

Level measurement of bulk materials in storage hoppers, material bins and large storage facilities.

 

5.Food & Pharmaceutical Processing

Selected liquid level measurement applications using the MPS7200 hygienic configuration.

 

6.Dusty Industrial Environments

Radar level measurement in applications involving strong dust or steam, subject to antenna selection and installation conditions.

 

Radar Level Sensor Antenna Options & Installation Guidelines

 Flexible Antenna Options for Different Installation Conditions

 

Plastic Rod Antenna

For selected liquid and simple process applications.

 
 

Horn Antenna

For selected liquid, powder and lump material applications.

 
 

Hygienic Antenna

For selected food and pharmaceutical liquid measurement applications.

 
 

PTFE Process-Sealed Antenna

For selected strongly corrosive liquid applications.

 
1

MPS7100

Ø50 / Ø80 Plastic Rod Antenna;
Ø80 Plastic Horn Antenna
2

MPS7101 

Compact Plastic Antenna;
Compact Plastic Horn Antenna;
Compact Integrated Antenna
4

MPS7200

Integrated Antenna;
Universal Purge Antenna
5

MPS7300

Process-Sealed Antenna

High Frequency Radar Level Meter Installation Position Guideline

21

Mixing Tanks

 
22

Solids Bin Installation

 
32

Flat-top Tank 

 
42

Conical-top Tank ;

Dome-roof Tank

 

Industrial Radar Level Meter Manufacturer

 Technical Selection Support

Get the Right Radar Level Transmitter for Your Process

Not every radar level transmitter configuration is suitable for every application. The MPS7000 Series offers different antenna types, housing materials, process connections and communication options.

To help identify a suitable model, our technical team can evaluate the following information:

Selection Item

Information Required

Measuring Medium

Liquid / Powder / Granules / Lump Material

Tank Height

Actual measuring range

Tank Type

Storage Tank / Reactor / Silo / Hopper

Process Temperature

Normal and maximum temperature

Process Pressure

Operating pressure

Tank Connection

Flange / Thread / Hygienic Clamp

Medium Properties

Corrosiveness, dust, steam, etc.

Output Requirement

4–20 mA / HART / LoRa

Installation Conditions

Internal obstacles and available space

Send us your application details. We can review the operating conditions and recommend a suitable MPS7000 configuration for your project.

Get Your Model Recommendation

Share your operating conditions with Radar Level Transmitter Factory to start a technical discussion.

  • Application and measuring medium
  • Required measuring range
  • Operating temperature and pressure
  • Preferred output and process connection

2026-11-04112929500-

Need help with model selection?

FAQ 

What is the measuring range of the MPS7000 radar level transmitter?

 The MPS7000 Series offers measuring range options of up to 120 meters. The actual range depends on the specific model, antenna configuration and application conditions.

Can the MPS7000 measure both liquids and solids?

Yes. The series includes configurations for liquid and solid level measurement. Different antenna types are available for selected liquids, powders and lump materials.

What is the measurement accuracy of the MPS7000 Series?

The maximum measurement accuracy is ±2 mm under standard laboratory conditions. Actual performance depends on antenna size, medium reflectivity, installation position and possible interference reflections.

Can the radar level transmitter be used in dusty environments?

The series is designed for applications involving strong dust and steam. The antenna configuration and installation conditions should be evaluated according to the specific process.

Can the MPS7000 measure corrosive liquids?

Yes. The MPS7300 configuration uses a PTFE process-sealed antenna for selected strongly corrosive liquid applications. The medium compatibility should be confirmed before selection.

How do I choose the right radar antenna?

Antenna selection depends on the measuring medium, required range, tank structure, process conditions and available installation space. Please provide your application details for technical evaluation.

What information should I provide when requesting a quotation?

Please provide the measuring medium, tank height, required measuring range, process temperature, pressure, connection type and output requirements. A tank drawing or installation photo can also help with model selection.

More Than a Product – MPS7000 Series Supplier Technical Support for Your Application

 

Application-Based Selection

 

Technical Communication

Order & Delivery Coordination

After-Sales Assistance

Discuss Your Project

 

 

 

 

Hot Tags: mps7000 series 120 ghz fmcw radar level transmitter, China mps7000 series 120 ghz fmcw radar level transmitter manufacturers, suppliers, factory

Send Inquiry