Key Features of MPS7000 Series 120 GHz FMCW Radar Level Transmitter
- Highly Focused Beam: Ultra-narrow beam angle, down to 1°.Non Contact Radar Level Meter.
- Strong Signal: Excellent penetration and extended measuring range.
- Minimal Blind Zone: Near-zero blind zone for accurate measurement in small vessels.
- Easy Configuration: Multiple setup options via instrument keys, Bluetooth, PC software, or HART communicator.
MPS7000 Series 120 GHz FMCW Radar Level Transmitter Specification
| Parameter | Specification |
| Beam Angle | Min. 1° |
| Measurement Accuracy |
±2 mm |
| Max. Measuring Range | 120 m |
| Radar Frequency | 120GHz |
| Protection Rating | IP66/IP67 |
| Signal Frequency |
D-Band (Approx. 120 GHz) |
Radar Level Transmitter Detailed Model Selection

MPS7100 – Standard FMCW Radar Level Transmitter

MPS7101 – Compact FMCW Radar Level Meter

MPS7200 – Integrated & Sanitary FMCW industrial Radar Level Transmitter

MPS7300 – PTFE Process-Sealed FMCW Radar Level Transmitter
Not Sure Which Radar Level Transmitter Configuration Fits Your Application?
Tell us your medium, tank dimensions and operating conditions. Our technical team can help you identify a suitable MPS7000 model.
[Request Technical Support]
120 GHz FMCW Radar Measurement Principle
01. What Is FMCW Technology?
FMCW (Frequency Modulated Continuous Wave) is a radar measurement technology that continuously transmits frequency-modulated microwave signals and measures the frequency difference between transmitted and received signals.
02. How Does FMCW Radar Level Meter Measure Level?
- Signal Transmission: The radar antenna transmits frequency-modulated microwave signals toward the material surface.
- Signal Reflection: The signal is reflected by the material surface and received by the antenna.
- Signal Processing: The instrument analyzes the frequency difference between the transmitted and received signals to calculate the distance to the material surface.
- Level Calculation: The measured distance is converted into a level value based on the configured tank dimensions.
03. Why Use 120 GHz FMCW Technology?
Narrow Beam Angle: Minimum beam angle of 1°.
High Measurement Accuracy: Maximum accuracy of ±2 mm under standard laboratory conditions.
Long Measuring Range: Up to 120 m, depending on model and antenna configuration.
120GHz Radar Level Meter
Widely Used in Application
1.Liquid Storage Tanks
Continuous level measurement of liquids in storage tanks, including small tanks and industrial storage vessels.
2.Mixing Tanks & Reactors
Level monitoring in mixing tanks and reaction vessels, with antenna configurations selected according to internal structures and process conditions.
3.Powder & Bulk Material Silos
Continuous level measurement of powder and lump materials in industrial silos and bulk storage vessels.
4.Mining & Material Handling
Level measurement of bulk materials in storage hoppers, material bins and large storage facilities.
5.Food & Pharmaceutical Processing
Selected liquid level measurement applications using the MPS7200 hygienic configuration.
6.Dusty Industrial Environments
Radar level measurement in applications involving strong dust or steam, subject to antenna selection and installation conditions.
Radar Level Sensor Antenna Options & Installation Guidelines
Flexible Antenna Options for Different Installation Conditions
Plastic Rod Antenna
For selected liquid and simple process applications.
Horn Antenna
For selected liquid, powder and lump material applications.
Hygienic Antenna
For selected food and pharmaceutical liquid measurement applications.
PTFE Process-Sealed Antenna
For selected strongly corrosive liquid applications.

MPS7100

MPS7101

MPS7200

MPS7300
High Frequency Radar Level Meter Installation Position Guideline

Mixing Tanks

Solids Bin Installation

Flat-top Tank

Conical-top Tank ;
Dome-roof Tank
Industrial Radar Level Meter Manufacturer
Technical Selection Support
Get the Right Radar Level Transmitter for Your Process
Not every radar level transmitter configuration is suitable for every application. The MPS7000 Series offers different antenna types, housing materials, process connections and communication options.
To help identify a suitable model, our technical team can evaluate the following information:
|
Selection Item |
Information Required |
|---|---|
|
Measuring Medium |
Liquid / Powder / Granules / Lump Material |
|
Tank Height |
Actual measuring range |
|
Tank Type |
Storage Tank / Reactor / Silo / Hopper |
|
Process Temperature |
Normal and maximum temperature |
|
Process Pressure |
Operating pressure |
|
Tank Connection |
Flange / Thread / Hygienic Clamp |
|
Medium Properties |
Corrosiveness, dust, steam, etc. |
|
Output Requirement |
4–20 mA / HART / LoRa |
|
Installation Conditions |
Internal obstacles and available space |
Send us your application details. We can review the operating conditions and recommend a suitable MPS7000 configuration for your project.
Get Your Model Recommendation
Share your operating conditions with Radar Level Transmitter Factory to start a technical discussion.
- Application and measuring medium
- Required measuring range
- Operating temperature and pressure
- Preferred output and process connection

Need help with model selection?
FAQ
What is the measuring range of the MPS7000 radar level transmitter?
The MPS7000 Series offers measuring range options of up to 120 meters. The actual range depends on the specific model, antenna configuration and application conditions.
Can the MPS7000 measure both liquids and solids?
Yes. The series includes configurations for liquid and solid level measurement. Different antenna types are available for selected liquids, powders and lump materials.
What is the measurement accuracy of the MPS7000 Series?
The maximum measurement accuracy is ±2 mm under standard laboratory conditions. Actual performance depends on antenna size, medium reflectivity, installation position and possible interference reflections.
Can the radar level transmitter be used in dusty environments?
The series is designed for applications involving strong dust and steam. The antenna configuration and installation conditions should be evaluated according to the specific process.
Can the MPS7000 measure corrosive liquids?
Yes. The MPS7300 configuration uses a PTFE process-sealed antenna for selected strongly corrosive liquid applications. The medium compatibility should be confirmed before selection.
How do I choose the right radar antenna?
Antenna selection depends on the measuring medium, required range, tank structure, process conditions and available installation space. Please provide your application details for technical evaluation.
What information should I provide when requesting a quotation?
Please provide the measuring medium, tank height, required measuring range, process temperature, pressure, connection type and output requirements. A tank drawing or installation photo can also help with model selection.
More Than a Product – MPS7000 Series Supplier Technical Support for Your Application
Application-Based Selection
Technical Communication
Order & Delivery Coordination
After-Sales Assistance
Hot Tags: mps7000 series 120 ghz fmcw radar level transmitter, China mps7000 series 120 ghz fmcw radar level transmitter manufacturers, suppliers, factory