VFD Vortex Flow Meter

VFD Vortex Flow Meter

The VFD Anti-Vibration Vortex Flow Meter adopts advanced digital signal processing technology to overcome the limitations of conventional vortex flow measurement. It can maintain accurate measurement under pipeline vibration levels of up to 3g and at fluid flow velocities as low as 0.2 m/s.
Description
VFE

Key Features of the VFD/VFT Anti-Vibration Vortex Flow Meter

Advanced FFT Signal Processing: Uses advanced Fast Fourier Transform (FFT) spectrum analysis technology for flow signal processing.

High Stability and Vibration Resistance: Designed to maintain stable measurement performance in environments with pipeline vibration.

Low Flow Velocity Measurement: Measures liquid flow velocities as low as 0.2 m/s.

High Reliability and EMI Resistance: Uses isolation technology for vortex signal processing to provide strong resistance to electromagnetic interference (EMI).

Low Power Consumption: Features a low-power design, with an operating current of less than 4 mA and total power consumption below 100 mW.

Vortex Flow Meter Data Sheet

Accuracy Class 1.0 (Gas); 0.5 (Liquids, Maximum)
Nominal Diameter DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300, DN350, DN400, DN450, DN500, DN600
Pressure Rating 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, ANSI 150, ANSI 300 (Other pressure ratings available upon agreement)
Sensor Wetted Parts Material 304 Stainless Steel, 316L Stainless Steel, Hastelloy C (Other materials available upon agreement)
Ingress Protection Rating (IP Rating) IP65, IP66, IP67
Explosion-Proof Rating

Intrinsic Safety: Ex ia IIC T1–T6 Ga

Integral Flameproof: Ex db IIC T1–T6 Gb

Remote Flameproof: Ex db eb IIC T1–T6 Gb

Intrinsic Safety for Dust: Ex ia IIIC T200 80°C Da

Flameproof for Dust: Ex tb IIIC T80°C Db

Medium Temperature Range -40°C to +200°C (Standard Model); -40°C to +400°C (High-Temperature Model)
Ambient Temperature -30°C to +70°C
Repeatability ±0.3%
Turndown Ratio 1:20 (Up to 1:30)
Flow Velocity Range Liquid: 0.3–7 m/s; Gas: 3–60 m/s; Steam: 2.5–60 m/s
Cable Gland G1/2", NPT1/2", M20 × 1.5
Power Supply Voltage External Power Supply: 16.5–42 VDC (For HART communication, a minimum load resistance of 250 Ω and a 21.5 VDC power supply are required); Modbus: 21.6–26.4 VDC; FF: 9–32 VDC
Output Signal Analog Output: 4–20 mA; Pulse Output
Communication Protocol HART; Modbus (RS485); FF

Working Principle of the Vortex Flow Meter

fjxv2OKYo

A vortex flow meter is a fluid oscillation flow meter based on the Kármán vortex street principle. When a non-streamlined bluff body is placed in a flowing fluid, two alternating rows of vortices are generated on either side of the body downstream.

-2

 
Our factory & quipment
 

Quality Control

-1
Four Intelligent Flow Meter Manufacturing Production Lines
2026-10-28152106134
Automatic Pressure Testing
2026-10-28152149672
Automatic Welding
2026-10-28152358233
Automatic Leak Testing
2026-10-28152453114
Automatic Flow Calibration
3
Ultra-High Flow Velocity Calibration Laboratory

Customized Complete Flow Measurement Solutions

 

6

Application
7

For Pharmaceutical Reactor Systems

8

For the Metallurgical Industry

10

       For the Power Industry

1
2
3
7

 

 

 

 

 
 

 

 

Hot Tags: vfd vortex flow meter, China vfd vortex flow meter manufacturers, suppliers, factory

Send Inquiry