Key Features of the VFD/VFT Anti-Vibration Vortex Flow Meter
Advanced FFT Signal Processing: Uses advanced Fast Fourier Transform (FFT) spectrum analysis technology for flow signal processing.
High Stability and Vibration Resistance: Designed to maintain stable measurement performance in environments with pipeline vibration.
Low Flow Velocity Measurement: Measures liquid flow velocities as low as 0.2 m/s.
High Reliability and EMI Resistance: Uses isolation technology for vortex signal processing to provide strong resistance to electromagnetic interference (EMI).
Low Power Consumption: Features a low-power design, with an operating current of less than 4 mA and total power consumption below 100 mW.
Vortex Flow Meter Data Sheet
| Accuracy Class | 1.0 (Gas); 0.5 (Liquids, Maximum) |
| Nominal Diameter | DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300, DN350, DN400, DN450, DN500, DN600 |
| Pressure Rating | 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, ANSI 150, ANSI 300 (Other pressure ratings available upon agreement) |
| Sensor Wetted Parts Material | 304 Stainless Steel, 316L Stainless Steel, Hastelloy C (Other materials available upon agreement) |
| Ingress Protection Rating (IP Rating) | IP65, IP66, IP67 |
| Explosion-Proof Rating |
Intrinsic Safety: Ex ia IIC T1–T6 Ga Integral Flameproof: Ex db IIC T1–T6 Gb Remote Flameproof: Ex db eb IIC T1–T6 Gb Intrinsic Safety for Dust: Ex ia IIIC T200 80°C Da Flameproof for Dust: Ex tb IIIC T80°C Db |
| Medium Temperature Range | -40°C to +200°C (Standard Model); -40°C to +400°C (High-Temperature Model) |
| Ambient Temperature | -30°C to +70°C |
| Repeatability | ±0.3% |
| Turndown Ratio | 1:20 (Up to 1:30) |
| Flow Velocity Range | Liquid: 0.3–7 m/s; Gas: 3–60 m/s; Steam: 2.5–60 m/s |
| Cable Gland | G1/2", NPT1/2", M20 × 1.5 |
| Power Supply Voltage | External Power Supply: 16.5–42 VDC (For HART communication, a minimum load resistance of 250 Ω and a 21.5 VDC power supply are required); Modbus: 21.6–26.4 VDC; FF: 9–32 VDC |
| Output Signal | Analog Output: 4–20 mA; Pulse Output |
| Communication Protocol | HART; Modbus (RS485); FF |
Working Principle of the Vortex Flow Meter

A vortex flow meter is a fluid oscillation flow meter based on the Kármán vortex street principle. When a non-streamlined bluff body is placed in a flowing fluid, two alternating rows of vortices are generated on either side of the body downstream.

Our factory & quipment
Quality Control






Customized Complete Flow Measurement Solutions

Application

For Pharmaceutical Reactor Systems

For the Metallurgical Industry

For the Power Industry




Hot Tags: vfd vortex flow meter, China vfd vortex flow meter manufacturers, suppliers, factory